Excerpt from Liposuction, Techniques: Internal Ultrasound-AssistedSynonyms, Key Words, and Related Terms: internal ultrasound-assisted lipoplasty, body contouring using internal ultrasonic assistance, liposuction, liposuction ultrasound, internal ultrasound, ultrasound-assisted liposuction Please click here to view the full topic text: Liposuction, Techniques: Internal Ultrasound-AssistedMichele Zocchi in Italy and Ralph Kloen in the United States are credited with developing and introducing internal ultrasound–assisted liposuction (UAL).1, 2 Industrial applications of high-energy ultrasound, as well as medical imaging applications of low-energy ultrasound, have been used for many years. The use of ultrasound as an ablative tool in surgery has been well established in neurosurgery and general surgery applications. Zocchi's interest in ultrasound was originally for harvesting collagen from aspirated fat. The observations that adipose tissues were effectively emulsified while connective tissue structures were preserved in vitro led to the concept of using ultrasound adjunctively in vivo. This led to clinical use of first-generation devices (eg, SMEI, Casales), which used blunt solid probes 4-6 mm in diameter followed by aspiration with standard cannulas. The promise of enhanced fat removal with minimal blood loss, claims of improved skin retraction, and safer large-volume procedures resulted in intense interest in UAL. However, enthusiasm was tempered by reports of skin burns, dysesthesias, and high seroma rates. Although considerable debate remains concerning the long-term effects and clinical use of UAL, it has become a well-established tool in the body-contouring armamentarium. Please click here to view the full topic text: Liposuction, Techniques: Internal Ultrasound-Assisted |
| About Us | Privacy | Code of Ethics | Terms of Use | Contact Us | Advertising | Institutional Subscribers |
|
|
|||
|
| Medicine is a constantly changing science and not all therapies are clearly established. New research changes drug and treatment therapies daily. The authors, editors, and publisher of this journal have used their best efforts to provide information that is up-to-date and accurate and is generally accepted within medical standards at the time of publication. However, as medical science is constantly changing and human error is always possible, the authors, editors, and publisher or any other party involved with the publication of this article do not warrant the information in this article is accurate or complete, nor are they responsible for omissions or errors in the article or for the results of using this information. The reader should confirm the information in this article from other sources prior to use. In particular, all drug doses, indications, and contraindications should be confirmed in the package insert. FULL DISCLAIMER |